Products
Low Temperature Butterfly Valve
  • Low Temperature Butterfly ValveLow Temperature Butterfly Valve

Low Temperature Butterfly Valve

Dafugui's Low Temperature Butterfly Valve is suitable for industrial control systems with media temperatures ranging from -40℃ to -253℃, primarily used in cryogenic fluid systems such as liquefied natural gas, liquid oxygen, and petrochemical tail gas separation. Since its inception, Dafugui has always prioritized technology import and independent innovation, obtaining numerous certifications and becoming a preferred supplier in many industries.

Dafugui Low Temperature Butterfly Valves feature a soft seal, a butterfly structure, and a flange connection. They allow for bidirectional flow and are suitable for media such as mud and dust. We currently offer a full range of sizes and diameters to suit your needs. For further information or to customize butterfly valves suitable for low-temperature environments, please contact us for more details.


Product Parameters

Nominal Diameter: Conventional range: DN50~DN1500 (NPS2~NPS60)
Special customization: up to DN2000 (NPS80)
Advantage pipe section: DN200~DN800 (NPS8~NPS32) are the most widely used
Nominal Pressure: International system: PN10~PN260
American standard system: Class150~Class1500(ASME B16.34)
Ultra high voltage type: Special design can reach Class 900 and above
temperature range: Conventional low temperature: -29 ℃~-50 ℃ (liquid CO ₂, refrigerant (R404A, etc.))
Deep Low Temperature: -50 ℃~-101 ℃ (liquefied ethylene (LEG), liquid ammonia)
Ultra low temperature type: -101℃~-196℃ (LNG(-162℃)、(-196℃))
Extreme low temperature: -196~-269 ℃ (liquid hydrogen (-253 ℃), liquid helium (-269 ℃)
design standards: ASME、ISO、BS、EN、MESC、GOST、GB
Flange Standard: ASME B16.5, ASME B16.47, EN 1092, ISO 7005, JIS B2220, GOST 3325
sealed structure: Elastic soft seal: Double eccentric soft seal structure
Metal hard seal: Three eccentric, four eccentric, and five eccentric metal sealing structures
connection type: Double flange type (LNG storage tank pipeline, easy to disassemble and maintain, requiring prevention of cold shrinkage leakage)
Docking welding type (there is no risk of leakage in high-pressure liquid oxygen pipelines, and deep cryogenic treatment is required after welding)
Main material: Low temperature carbon steel: LCB、LCC、LC1、LC3
austenitic stainless steel: CF8、CF8M、CF3、CF3M、321、347、XM-19
Nickel based alloys: Inconel 625, Inconel 718, Monel 400, Monel K500, Nitronic 60
Special alloy: Titanium alloy, aluminum alloy, copper alloy


Low Temperature Butterfly Valve


Key Features

1. Cryogenic Sealing Guarantee: The main sealing surface of the Low Temperature Butterfly Valve utilizes a nickel-based alloy welding process, withstanding temperatures as low as -196℃. A two-stage sealing structure composed of bellows and graphite winding ensures a leakage rate of no more than 50ppm. The valve stem's dual sealing system, combined with a spring-reinforced stuffing box, meets vacuum-level sealing requirements. All valve seat components are made of low-temperature annealed stainless steel and have undergone intergranular corrosion testing to eliminate the risk of cold flow deformation.

2. Cryogenic Embrittlement Resistance Design: The valve body of the Low Temperature Butterfly Valve undergoes cryogenic austenitization stabilization treatment, and the butterfly plate is cryogenically machined with liquid nitrogen.

3. Wide Temperature Range Adaptability: The extended valve cover forms a cold insulation barrier, and with an optional vacuum jacket, thermal stability can be maintained at -100℃. The wedge-shaped self-tightening valve seat design ensures that the sealing pressure remains above 6.5 MPa even with temperature fluctuations, improving system reliability.

4. Typical Operating Condition Verification Record: Suitable for liquid nitrogen storage and transportation units and ethylene cryogenic separation units, it has demonstrated excellent stability through long-term industrial verification. 5. Special manufacturing process: Each Low Temperature Butterfly Valve undergoes 100 deep cryogenic cycle tests before leaving the factory to ensure consistent performance.


Instructions for Use

1. Pre-cooling Treatment: Before using the Low Temperature Butterfly Valve, it must be pre-cooled using a gradient method. First, purge the air with nitrogen and cool to the operating temperature at a rate of less than 30°C/hour. Direct introduction of cryogenic media is strictly prohibited to avoid cold cracking of the sealing surface.

2. Installation Direction Control: The medium flow direction marking on the valve body must be consistent with the pipeline flow direction. Reverse installation of a single-eccentric structure will increase the leakage rate by 10 times.


Maintenance Requirements

1. Regular Maintenance

It is recommended to perform bolt preload check every 3 months, bellows seal test every 12 months, and complete cryogenic cycle test every 2 years.

2. Emergency Maintenance

Immediate shutdown is required in the following situations:

* Frost buildup on valve body surface exceeds 30% of surface area

* Actuator malfunction delay exceeds 50% of standard value

* Stuffing gland leakage rate suddenly exceeds 1000 ppm


Send Inquiry
Contact Info
Dafugui is a leading China manufacturer and supplier of flanges, valves, and pipe fittings since 2006. Welcome to our website! For inquiries about our products or pricelist, please leave your email to us and we will be in touch within 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept